ORGLIST: Reverse phase LC followup

Date view Thread view Subject view Author view Attachment view

From: Jim Sims (jsims$##$ucrac1.ucr.edu)
Date: Thu Oct 28 1999 - 12:40:18 EDT


Reverse phase is separates on a different principle than regular phase (see
texts ). Some molecules separate better on one than the other. We find
that for very polar or very nonpolar molecules reverse phase is usually
better. For intermediate polarity it can be a toss up. We prefer normal
phase for preparative work because we normally can load the column with
more sample and maintain the separation. Solvent choice can greatly
influence the separation on either phase.








>
>I guess I would ask you a similar question (and I ask it out of ignorance,
>since I'm pretty new to reverse phase). Why is reverse phase the method of
>choice now, both for analytical and prep work? For "normal" organic
>synthesis (i.e., nonzwitterionic compounds, high organic solubility, etc.)
>isn't straight phase chromatography using nonaqueous mixtures just as
>effective?
>*******************
>
>There's my response...if the collected wisdom of the list has further
>suggestions, I would love to hear them.
>
>best regards,
>
>Joe Bozell
>Senior Chemist
>National Renewable Energy Lab
>Golden, CO
>USA
>
>__________________
>
>ORGLIST - Organic Chemistry Mailing List
>Website and Archive: http://www.orglist.net/
>List coordinator: Joao Aires de Sousa (jas$##$mail.fct.unl.pt)
>

Professor Jim Sims
Department of Plant Pathology
University of California, Riverside
Riverside, CA 92521
Voice: 909 787 4127
FAX 909 787 4294


__________________

ORGLIST - Organic Chemistry Mailing List
Website and Archive: http://www.orglist.net/
List coordinator: Joao Aires de Sousa (jas$##$mail.fct.unl.pt)


Date view Thread view Subject view Author view Attachment view